TUV审核不符合项
1\
Process: The special characteristics and layout inspection determination of APQP process is not effective.
Evidence of non-conformance:
At design and development of project SATA, P/N#112.06.053.02,
a) the paint thickness (>0.02mm) special characteristic is not identified in control plan.
b) the layout and functional inspection is not included in the control plan.
2\
Process: Evaluation of customer satisfaction process is not effective.
Evidence of non-conformance:
Customer satisfaction is evaluated at Jun/2007. The customer satisfaction evaluation report did not cover the objective performance data, including the delivered quality, ppm, on time delivery performance.
Process: The special characteristics and layout inspection determination of APQP process is not effective.
Evidence of non-conformance:
At design and development of project SATA, P/N#112.06.053.02,
a) the paint thickness (>0.02mm) special characteristic is not identified in control plan.
b) the layout and functional inspection is not included in the control plan.
2\
Process: Evaluation of customer satisfaction process is not effective.
Evidence of non-conformance:
Customer satisfaction is evaluated at Jun/2007. The customer satisfaction evaluation report did not cover the objective performance data, including the delivered quality, ppm, on time delivery performance.